same input output signal name in simulink

14 次查看(过去 30 天)
I want to make code below by model (or stateflow) using Code Generation
if( var > 10){
var = 10;
}
In this case, upper 'var' is input of chart(or subsystem) and lower 'var' is output of chart.
So, it occurs signal complication if I use same variables name or I can't make same name of chart's input and output.
I can make this if sentance by using two variables, but I hope to make this by using one.
Thanks for your help.
Sincerely,
TaeHee Kwun.

采纳的回答

Phani Teja
Phani Teja 2019-7-16
编辑:Phani Teja 2019-7-16
Yeh It can be possible with Data store memory block.
Make a Variable 'Var' in stateflow and change its scope to Data store memory .
You can also control the variable storage class by resolving data store memory with simulink signal.
The generated code looks like:
/* Real-time model */
RT_MODEL_Chart_T Chart_M_;
RT_MODEL_Chart_T *const Chart_M = &Chart_M_;
/* Model step function */
void Chart_step(void)
{
/* Chart: '<Root>/Chart' */
/* Re-use inputs */
if (Var > 10) {
/* NEW_PATTERN */
Var = 10;
}
/* End of Chart: '<Root>/Chart' */
}
  2 个评论
TaeHee Kwun
TaeHee Kwun 2019-7-20
Thanks for your answer!
But, I can't still understand how to make this blocks...
If you can, can you upload some of your blocks?
Thanks.
sreedevi
sreedevi 2021-6-13
Hi ,Did you get an answer for the question.If yes please post it

请先登录,再进行评论。

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Simulink Functions 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by