Why are my simulink initial conditions sometimes not met, despite high priority?
7 次查看(过去 30 天)
显示 更早的评论
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.
1 个评论
Hari Krishna Ravuri
2019-7-31
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.
回答(1 个)
Martin
2023-10-4
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Thermal Analysis 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!