Why are my simulink initial conditions sometimes not met, despite high priority?

2 次查看(过去 30 天)
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.tf.PNG
  1 个评论
Hari Krishna Ravuri
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.

请先登录,再进行评论。

回答(1 个)

Martin
Martin 2023-10-4
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.

类别

Help CenterFile Exchange 中查找有关 Thermal Liquid Library 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by