Input ports (1, Action) If Action Subsystem' are involved in the loop?

116 次查看(过去 30 天)
I am trying to simulate a closed loop cooling system using simulink but facing this error continously.
If anyone can help me with this would be of great help?
I have uploded the file,if anyone can please run it and share the trouble shooting measures willbe of greta help.
I ahve uploded the mat variable file for initialization parameters of the model

回答(1 个)

Divya Yerraguntla
Divya Yerraguntla 2019-9-25
Hi Adit,
I could see an algebraic loop formed in your model by the signal coming to Total_pressure_BP input of Pump 1 subsystem. This is actually causing the issue. Try adding a Unit Delay block to the signal coming to Total_pressure_BP block.
For more information about identification and removal of algebraic loops have a look at these links:
Also in order to solve algebraic loops in models containing continuous blocks you could go through this link:
Hope it helps!

类别

Help CenterFile Exchange 中查找有关 Modeling 的更多信息

产品


版本

R2017a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by