why doesn't my hard stop in Double-Acting Actuator (IL-G) work?

2 次查看(过去 30 天)
I am using a Linear actuator with piston motion controlled by opposing hydraulic and gas chamber, which allows the setting of the piston stroke and starting position. When I plot the position of the piston on the scope it travels more than the piston stroke. I also integrated the flow from the liquid chamber and the volume discharged is greater than the stroke multiplied by the piston area. Is this a bug?

采纳的回答

Graham Moore
Graham Moore 2019-8-29
The answer is the stiffness of the stop was too small. The default value of stiffness 1e6 was allowing the piston to keep moving since the end point is not actually defined but just relies on the spring force implementing the stop. If the stiffness is too small the deformation just keeps going.

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Upgrading Hydraulic Models to Use Isothermal Liquid Blocks 的更多信息

标签

产品


版本

R2018b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by