Simulink 2019a To Workspace/Array gives a structure not an array
6 次查看(过去 30 天)
显示 更早的评论
I created a simple model with a step source and a To Workspace sink. I changed the Save Format to Array and ran the model. The data in the workspace appears as a structure, not an array. Is this a bug? I don't recall it worked this way in 2018b. How can I change the settings so the data is saved as an Array?
0 个评论
回答(1 个)
Urmila Rajpurohith
2020-4-9
Data in workspace appears as structure because single simulation ouput option is checked which return all simulation outputs as a single Simulink.SimulationOutput object
unchecking this option will give you the data in array format
To uncheck this option go to:
Modelconfiguration parameters -->Data import/export and uncheck single simulation ouput
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Sources 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!