Why does LinearFMWaveform require integer Sampling Rate / PRF ratios?
显示 更早的评论
Does anybody know why the LinearFMWaveform demands that this condition be met:
The quantity (SampleRate ./ PRF) is a scalar or vector that must contain only integers.
I am modeling a radar with a fixed sampling rate and a discrete set of PRFs. But I cannot make side-by-side comparisons when I have to change the sampling rate for each waveform. Does anybody know a way around this behavior?
回答(1 个)
Honglei Chen
2012-10-5
0 个投票
Hi Michael,
The pulse supposed to repeat itself at the PRF. If the ratio is not an integer, then the waveform cannot be started from the beginning. As a consequence, the LinearFMWaveform also cannot really output one pulse a time because a pulse is not represented by the integer number of points.
This being said, I am very curious about your case here. Would you mind sharing that in such a situation, how you would like the waveform to behave?
Thanks.
类别
在 帮助中心 和 File Exchange 中查找有关 Pulsed Waveforms 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!