C2000 CLA trigger using ADCINT source

2 次查看(过去 30 天)
Hello,
I am trying to synchronize the reading of ADC with the interrupts coming from EOC of the same ADC. The model I have s simple. As configured below. I am getting the following error. Any help is appreciated.
TopLevel.PNG
ePWM_Block.PNG
ADC_Config.PNG
Error.PNG

采纳的回答

Aditya Padmanabha
Hi Zak,
Please set the properties of the signal at ADC output to Cla1DataRam memory so that the variable is created in cla.
CLA_Settings.png
Also ensure you have selected c28035_cla.cmd for Linker command file in Configuration parameters -> Hardware Implementation tab with Boot From Flash enabled.
Hope it helps,
Aditya

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 C2000 Microcontroller Blockset 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by