How can I change the initial battery charge of the example microgrid in Matlab?
1 次查看(过去 30 天)
显示 更早的评论
Hello, I'm working with the example microgrid that comes with Matlab/Simulink as shown here:
It can be accessed by typing in 'power_microgrid' in the terminal.
The battery charge is initialized to 80%.
How can I change this value to something else, say 90%?
0 个评论
采纳的回答
Jeremy
2020-2-21
编辑:Jeremy
2020-2-21
If you right click on the Battery_Simple_Dynamics subsystem, you can go to Mask -> Look Under Mask. Here, you will see that the state of charge is being computed in this subsystem. The AH*0.2*3600 constant block after changing to AH*0.1*3600 I then see an initial charge state of 90%.
更多回答(1 个)
Fangjun Jiang
2020-2-21
Right click, Mask, Look under Mask
Find the Constant block showing "AH*0.2*3600". "0.2" is the determing value. Change it to be 0.1 to make the initial SOC as 90%.