Acquire and generate signals with NI USB-6003 simultaneously but at different rates?
19 次查看(过去 30 天)
显示 更早的评论
I need to acquire data using analog input while also generating a 0-10V control signal with the analog output. The output channel's max scan rate is 5000 scans/s which is fine, but I need my input channel to scan up to 50,000 scans/s.
The NI USB 6003 can sample up to 100,000 scans/s, but when I add an analog input and output channel to the same session I get this warning:
Warning: The Rate property was reduced to 5000 due to changes in the session configuration.
Do I need to use two different sessions, one for analog input and one for analog output? My understanding was that I would not be able to run two sessions at once then.
5 个评论
Walter Roberson
2020-3-6
The post includes a link to a Mathworks documentation example that says specifically that you cannot run two different speeds in the same session.
At the moment I do not find documentation that says that you cannot run multiple sessions on the same device. It sounds plausible, but I also seem to recall posts in which people did just that under some circumstances.
回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Analog Input and Output 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!