Xpc target data logging at different rate
1 次查看(过去 30 天)
显示 更早的评论
My xpc model rund at 100Hz. I want to log several data for a week non stop. However, the data doesn't need to be logged every 0.01s, only every 1s.
How can I log data at a different rate than my simulation steptime? And is it possible to log so many datapoints?
1 个评论
Gordon Weast
2012-10-31
Jan,
I believe that using the 'Decimation' parameter in a file scope should allow you to save a subset. In your case, set Decimation to 100 to log every 100th time step.
Gordon Weast, xPC Target Development
回答(1 个)
Ryan G
2012-10-23
Eventually I would suspect the system will run out of memory for one reason or another. However, you can use a file scope to log the data to a file on the host machine. See xpc data logging on the file exchange.
I would make sure as little as possible gets logged in memory since a week is a very long time for a sim in my opinion. Good Luck.
2 个评论
Ryan G
2012-10-23
It will repeat the values if you set it at a faster rate. If you set it for a slower rate, as you desire here, it will only pass through the value at the 1Hz rate. Go ahead and try it out in Simulink first to verify, but I know it will work as you desire.
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Target Computer Setup 的更多信息
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!