How to create/ simulate fault in asynchronous machine in simulink?
2 次查看(过去 30 天)
显示 更早的评论
How can I simulate the faults in the asynchronous machine ?ex: broken bar or stator winding.
0 个评论
回答(1 个)
Sabin
2025-1-30
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding slot level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point:
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Electrical Block Libraries 的更多信息
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!