AC/DC Three-Level PWM Converter
11 次查看(过去 30 天)
显示 更早的评论
AC/DC Three-Level PWM Converter is an example matlab file and why this file doesnt not work for negative active power reference.Does it needs to change the initial conditions set and if so how to do that ?
10 个评论
回答(1 个)
Mohsen Aleenejad
2020-7-30
The reason is that the topology is not physically able to follow the negative reference. The load consists of two parallel resistive branches. There is no power/energy generaor (at the right side of the converter) to constantly put back the energy into the 600V three phase system. As a rsult, the active power is always positive and Id cannot remain negative.
0 个评论
社区
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Power Converters 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!