AC/DC Three-Level PWM Converter

5 次查看(过去 30 天)
NN
NN 2020-6-29
AC/DC Three-Level PWM Converter is an example matlab file and why this file doesnt not work for negative active power reference.Does it needs to change the initial conditions set and if so how to do that ?
  10 个评论
NN
NN 2020-6-30
Thank you Mohsen.I i wll surely check these otpions
Mohsen Aleenejad
Mohsen Aleenejad 2020-6-30
I am happy that I could help.
Good Luck.

请先登录,再进行评论。

回答(1 个)

Mohsen Aleenejad
Mohsen Aleenejad 2020-7-30
The reason is that the topology is not physically able to follow the negative reference. The load consists of two parallel resistive branches. There is no power/energy generaor (at the right side of the converter) to constantly put back the energy into the 600V three phase system. As a rsult, the active power is always positive and Id cannot remain negative.

社区

更多回答在  Power Electronics Control

类别

Help CenterFile Exchange 中查找有关 MATLAB 的更多信息

产品


版本

R2019a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by