Invalid Simulink object name: loader

123 次查看(过去 30 天)
When i build an example model in simulink ,it occurs the error
The call to slrt_make_rtw_hook, during the exit hook generated the following error: Invalid Simulink object name: loader The build process will terminate as a result.
Caused by:
  • Invalid Simulink object name: loader
  • No block diagram 'loader' is loaded.
Component:Simulink,simulink real-time | Category:build model
  6 个评论

请先登录,再进行评论。

采纳的回答

Pablo Romero
Pablo Romero 2021-10-5
Check the error message on the target console, either by looking at the screen or with the 'getConsoleLog' function: https://www.mathworks.com/help/releases/R2018b/xpc/api/simulinkrealtime.utils.getconsolelog.html?s_tid=doc_ta
It will provide useful data about what the actual cause of the failure is.
  1 个评论
Stefanie Schwarz
Stefanie Schwarz 2023-4-5
If the error in the console is:
"Unable to load DLL dependency: KERNEL32.dll.GetFileSizeEx"
then you are probably affected by the bug described here:
But there can be possible other causes. Please contact MathWorks Technical Support for help: https://www.mathworks.com/support/contact_us.html

请先登录,再进行评论。

更多回答(0 个)