EEGlab ICAlabel not working with specific data
显示 更早的评论
I have 64 channel EEG data run through preprocessing steps before running ICA. I have run 18 datasets using the same process with no issues. I have 2 datasets where the ICA takes hours and then once the ICA is finished, this error occurs:
Error using ICL_feature_extractor (line 26)
Your ICA decomposition must be real to use ICLabel
Error in iclabel (line 52)
features = ICL_feature_extractor(EEG, flag_autocorr);
The data doesn't look any different than my other datasets. Any suggestions?
5 个评论
KSSV
2020-8-21
Which error?
Walter Roberson
2020-8-21
iclabel appears to be a third-party toolbox.
You could get that message if your ica generated nan or inf or complex values.
Rebecca Kenny
2020-8-21
Walter Roberson
2020-8-21
What shows up for
nnz(~isfinite(EEG))
if the result is not 0 then you have samples that are infinite or Not A Number (nan). nan is often used to indicate missing data.
Moiz Ashfaque
2024-10-24
Hi @Rebecca Kenny, did you get around to solve this error? I seem to be facing the same error with my 9 channels EEG data.