problem with working IF Block
14 次查看(过去 30 天)
显示 更早的评论
In if block subsystem,,,wen a control goes to else condition,,,my if condition subsystem will be reset to '0',,but i dont want it,,,i want to keep hold the last value of if control subsystem,,,anybody know how to make if control subsytem to hold the last calculated value
0 个评论
采纳的回答
TAB
2013-2-8
Double click output ports in your if action subsystem and set Output when disabled property to held.
1 个评论
更多回答(0 个)