Changing the x-axis from Time instead samples
23 次查看(过去 30 天)
显示 更早的评论
Hi everybody!
I'm a new user of Matlab, so I really appreciated your help. I'm doing the spectrogram of a chirp signal. Here is how I defined it:
fs = 1000;
t = 0:0.001:1;
y = chirp(t,60,1,20);
Later, I use the spectrogram as below, with a hamming window of 64 samples:
w1 = hamming (64);
spectrogram (y, w1, [], [], fs, 'yaxis');
The point is that when the graph is displayed, the x axis is in samples, and I would like to be in seconds. I try several things but I can´t do it. I atacched a copy of the graph.

So, I want that the x-axis be in time, not in number of samples. Can anybody help me? I apreciated so much,
Thanks!
0 个评论
采纳的回答
Star Strider
2020-11-9
When I run yoiur code in R2020b, the x-axis is labeled ‘Time (ms)’.
To convert them (and the x-axis label) to seconds:
fs = 1000;
t = 0:0.001:1;
y = chirp(t,60,1,20);
w1 = hamming (64);
spectrogram (y, w1, [], [], fs, 'yaxis');
Ax = gca;
xt = Ax.XTick;
Ax.XTickLabel = xt/1000;
Ax.XLabel.String = 'Time (sec)';
.
4 个评论