On which frequency i should apply DWT (wavelet transform), sampling frequency or output bandwidth

4 次查看(过去 30 天)
i have emotiv epoch for EEG signal acquisition. If band width of Emotiv is 2-43 Hz and sampling frequency is 128 Hz then upto which i should apply DWT, On 2-43 Hz or On 128 Hz?????

采纳的回答

Wayne King
Wayne King 2013-3-3
If your sampling frequency is 128 Hz, then the approximate frequency bands in the DWT are already determined by the sampling frequency.
They are: (Scaling filter band on left, wavelet filter band on right)
[0 32] [32 64] Hz
[0 16] [16 32] Hz
[0 8] [8 16] Hz
[0 4] [4 8] Hz
and so on.
You notice that the band 2-43 Hz is best localized (but certainly not perfectly) in the 1st level approximation coefficients.
What not just use a good filter if you are just using the DWT to perform a frequency-filtering of your signal?

更多回答(0 个)