Hello,
I have a question regarding a parameter in the heat exchanger block in simscape. When I select the Nusselt-Reynolds-Prandlt correlations for the heat transfer parametrization I have to define the "Length of flow path for heat transfer". What is this parameter exactly defining?
At first, I thought it was the total length of the pipe of the heat exchanger for each side, as the default parameter was 1 meter. But reading the description I got confused as it says: "Characteristic length traversed in heat transfer between fluid and wall. This length factors in the calculation of the hydraulic diameter from which the heat transfer coefficient and the Reynolds number, as defined in the tabulated heat transfer parameterizations, derives.", reading this description makes me think it is the distance from the center of the pipe to the exterior face of the same.
If anyone could clarify this It would be great
Thank you in advance,
0 个评论
采纳的回答
Sarah McElman
2020-12-7
Hi Carlos,
Your first impression is correct.
The Length of flow path for heat transfer corresponds to the length of the piping or channel between the exchanger inlet and outlet. I've let our documentation team know about the error in the parameter definition section.
Please let me know if you have any further questions.
Best,
Sarah
2 个评论
Sarah McElman
2020-12-9
Hi Carlos,
Would you be able to share your model? I'd have a better idea of what the problem may be that way.
Best,
Sarah
更多回答(1 个)
carlos Hernando
2020-12-9
2 个评论
Sarah McElman
2020-12-9
Hi - you should be able to attach your .slx file to a comment or the original posting. Which version of Matlab are you using?