RTWT workshop is used to generate C code for a Simulink model and start/ stop of the model is controlled through a VC++ GUI (Visula studio 2008) using set_param() commands. This is working fine. But when it is desired to pause the model execution using a similar method (set_param(‘modelname’,’SimulationCommand’,’pause’)), we find that the model does not pause. We have also tried using a assertion block, but of no use. We wanted to know the conditions in which any model cannot be paused (because we have tried the same in a very simple simulink model and it works).

采纳的回答

Jan Houska
Jan Houska 2013-3-25
Code running in real time generally cannot be paused. That would contradict its purpose to run in real time. For example, if the code controls an externally connected device, pausing the code would get the control algorithm out of sync with the device state. After resuming the paused code the results will be unpredictable.
Please be more specific about what you are trying to achieve by pausing real-time code. Most likely, there are other ways to get the desired effect.
  4 个评论
Kamali
Kamali 2013-4-3
Thanks. I could pause/continue the model execution using an enable subsystem. This solves our problem.
vineetha
vineetha 2013-4-26
Is it possible to get data from the model while pausing the simulation using subsystem. I have tried retrieving data using enabled subsystem, but it is not working. Is there any way to get data from RTWT while model is running?

请先登录,再进行评论。