FIR filter has output of same length as its input?
4 次查看(过去 30 天)
显示 更早的评论
If the input signal has length L samples, impulse repsonse has length M samples, entering these L samples to FIR filter using conv function, will get L+M-1 output samples, while entering these L samples to FIR fitler, the output has L samples only instead of L+M-1 samples . Also, I'd like to know which L samples does FIR filter choose from L+M-1 samples (total samples) to be its output ?.
0 个评论
采纳的回答
Bruno Luong
2020-12-27
编辑:Bruno Luong
2020-12-27
There is the the difference equation in the "Rational Transfer Function" part of the doc. x(i) with i<=0 are supposed to be 0.
and you can figure out easily just by experiment
>> x=rand(1,10)
x =
0.1576 0.9706 0.9572 0.4854 0.8003 0.1419 0.4218 0.9157 0.7922 0.9595
>> b=rand(1,3)
b =
0.9340 0.6787 0.7577
>> conv(x,b) % <= 'full' option
ans =
0.1472 1.0135 1.6722 1.8385 1.8022 1.0435 1.0966 1.2491 1.6810 2.1277 1.2515 0.7270
>> filter(b,1,x)
ans =
0.1472 1.0135 1.6722 1.8385 1.8022 1.0435 1.0966 1.2491 1.6810 2.1277
更多回答(0 个)
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!