DWARF Parser internal error: Parser::describeSymbol xcpDummyDoubleVariable is not a global variable.

94 次查看(过去 30 天)
The project is loaded from "Embedded Coder Support Package for STMicroelectronics Discovery Boards".
If pressing "run" or "Build,Deploy & Start",there is no error returned.pressing the "Monitor & turn" button will return errors.
The errors returned are shown below:
External Mode Open Protocol Connect command failed
Caused by:
DWARF Parser internal error: Parser::describeSymbol xcpDummyDoubleVariable is not a global variable
Component:Simulink | Category:Block diagram error
Unable to connect to the 'STM32F746G-Discovery' target for 'stm32f746gdiscovery_audio_equalizer'.
Component:Simulink | Category:Model error
If other modules are commented out and only input and output are left, as shown in the figure, this error message will still be reported. This problem will not appear on the stm32f4 disco development board. Note that stm32f4 uses an additional ttl-233.
  5 个评论

请先登录,再进行评论。

采纳的回答

bert de Jong
bert de Jong 2022-3-7
编辑:bert de Jong 2022-3-7
I think the issue is that the xcpDummyDoubleVariable symbol is optimized by the linker, as it is not used anywhere except for checking the size of a double variable. You can prevent this optimization from happening by instructing the linker to keep this variable. This setting is however compiler dependent. In my case, I am using a compiler from IAR, however in the manual of your compiler you can probably find the right setting for you.
This setting can be added in your modelsettings -> Code Generation menu.
  1. Set 'Build configuration' to 'Specify'
  2. In the 'Linker' or 'C++ Linker' field add the setting to keep the xcpDummyDoubleVariable symbol. In my case this is: $(ldebug) $(conflags) $(LIBS_TOOLCHAIN) --keep xcpDummyDoubleVariable
A second option would be to modify the xcp_ext_common.c file. this file is located in: [MatlabFolder]\toolbox\coder\xcp\src\target\ext_mode\src\xcp_ext_common.c
After line 623 add the following and save: xcpDummyDoubleVariable = (extmodeDouble_T) 0;
This way, the xcpDummyDoubleVariable is actually 'used', and is therefore not optimized away.
Hope this helps (though it is a bit of a workaround).
  9 个评论
chen junbing
chen junbing 2024-5-8
Hi:
Do you solve the problem?
I also have the same problem. 'DWARF Parser internal error: Parser::describeSymbol xcpDummyDoubleVariable is not a global variable'

请先登录,再进行评论。

更多回答(4 个)

Nithin
Nithin 2023-12-5
This issue may occur if Monitor & Tune is run without logging any signal or if there are no outports connected in the Simulink model. Ensure a signal is selected for logging in the model. After doing so, the error message should disappear and external mode should run as expected.
If the problem still persists, contact MathWorks Technical Support: If the problem still persists https://in.mathworks.com/support/contact_us.html

bert de Jong
bert de Jong 2022-6-28
Please note that this issue has been fixed in R2022a.
  2 个评论
Vivek
Vivek 2023-3-30
I tried to implement it but its not working.... I have matlab R2021a and hardware interfaced is jetson nano. I tried to modify the code as specified in above solution but its not working...

请先登录,再进行评论。


Sanath
Sanath 2023-9-8
Hi, I still have this issue in MATLAB 2023a, my serial communcation is not working.has anyone found a solution?
  2 个评论
Mahesh Bharath Pudutha
Hello,
Even I am facing the same issue, The controller which I am using is TMS320F28335 and the Matlab version is 2023a. Requesting for any leads and help.
Sanath
Sanath 2023-9-25
While i have not been able to identify the source of the issue, this is what i think is a work around for me. My connect function doesnt work still but monitor and tune works fine.
  1. Try increasing the baud rate to max possible by trial and error and make sure you have dedicated timer swtiched off in external mode.
  2. Select the correct com port for STM and for newer versions, the Virtual COM port is to be connected.
  3. This is the work around which worked for me, I run the "STM external mode" example, once it works, I edit and build my whole model in the same example file.

请先登录,再进行评论。


Rakesh
Rakesh 2023-9-25
Hi, I still have this issue in MATLAB 2023a, my serial communcation is not working.has anyone found a solution?
External Mode Open Protocol Connect command failed
Caused by:
DWARF Parser internal error: Parser::describeSymbol xcpDummyDoubleVariable is not a global variable
Component:Simulink | Category:Block diagram error
Unable to connect to the 'STM32F746G-Discovery' target for 'stm32f746gdiscovery_audio_equalizer'.
Component:Simulink | Category:Model error
  2 个评论
Sanath
Sanath 2023-9-25
While i have not been able to identify the source of the issue, this is what i think is a work around for me. My connect function doesnt work still but monitor and tune works fine.
  1. Try increasing the baud rate to max possible by trial and error and make sure you have dedicated timer swtiched off in external mode.
  2. Select the correct com port for STM and for newer versions, the Virtual COM port is to be connected.
  3. This is the work around which worked for me, I run the "STM external mode" example, once it works, I edit and build my whole model in the same example file.
vallela
vallela 2023-9-26
I am facing the same problem. In my case monitor and tune also not working. where can i find the stm external mode example. it would be really helpful if you can help me. where can I increase the baud rate.