how to model a switch with two different conditions for activation and deactivation
5 次查看(过去 30 天)
显示 更早的评论
Hello:
I have a problem modeling a dynamic system. Now I understand the problem and know a possible solution. My problem is to transform the thought logic into Simulink language.
Let's describe what I want to do:
I want to activate or deactivate a subsystem based on a signal value (0 or 1) in a discrete subsystem. The activation is conditioned by another two conditions: condition A must be ON and does not matter the value of condition B. At this point, if condition A turns to off, the subsystem must be active until condition B is ON (How to maintain this value?). Finally the subsystem is deactivated and it will wait for another instant when condition A is ON again.
Thank you in advance for your help!!
0 个评论
采纳的回答
Arnaud Miege
2011-5-9
Can you use Stateflow? Something like this should do it:
where A_in and B_in are defined as boolean inputs to the chart and out as an output from the chart that can be used to enable a subsystem.
HTH,
Arnaud
6 个评论
Arnaud Miege
2011-5-10
This is because you haven't defined what ind_presion is in all cases (execution path). For example when you have:
if PABS_cdyc && ind_presion_last==1 % DEACTIVATION
ind_presion = 0;
end
you need an else to define ind_presion when 'PABS_cdyc && ind_presion_last == 1' isn't true.
I would suggest trying to combine all the logic into one if...else statement, possibly with some additional nested if...else statements if necessary.
更多回答(1 个)