Error in Simulink

what kind of error is this?
"Simscape components in Celula are not connected to a Solver Block." Celula is the name of the program...

1 个评论

Please don't email me directly. As Rob pointed, and as the error message suggests, you need to connect your Simscape network to a Solver Block. I would suggest your read the documentation, in particular the section entitled "Modeling Physical Systems":
http://www.mathworks.com/help/releases/R2011a/toolbox/physmod/simscape/ug/bp5oili.html
Arnaud

请先登录,再进行评论。

回答(1 个)

Rob Graessle
Rob Graessle 2011-5-9

3 个投票

When your block diagram contains Simscape components, the physical network circuit must be connected to at least one Solver Configuration block. This block specifies parameters for the simulation of the physical model.

1 个评论

Actually, it's *exactly* one Solver Configuration per Simscape network.

请先登录,再进行评论。