How to realize dynamic size bus as input and output like bus assignment module?

3 次查看(过去 30 天)
How to realize dynamic size bus as input and output like bus assignment module?

回答(1 个)

Leepakshi
Leepakshi 2025-5-2
Hi Feng,
In Simulink, the Bus Selector block requires the structure of the input bus (the names and number of signals) to be defined at design time. It does not support dynamic adaptation to arbitrary bus structures at runtime. For a library function to work with different bus types, you must define a bus object that includes all possible signals you might need (the union of all fields) and configure the Bus Selector to select from these. If some signals are unused in a particular context, they can be left unconnected or set to default values. True dynamic selection based on the incoming bus structure is not supported; the bus structure must be fixed and known when you build the library function.
Refer to below documentation for more information:
Hope this helps!

类别

Help CenterFile Exchange 中查找有关 Simulink 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by