Simscap Scope shows wrong data.

2 次查看(过去 30 天)
I am simulating an RL Circuit.
when i take simulation time 10 ses, the graph on scope is nonsence.
if anyone know, how to fix it. please let me know.
Best Regards.
  3 个评论
Farhad Barati
Farhad Barati 2021-4-27
Hello Muhammad,
Try to reduce the step-size to get an accurate result.
Mohammadreza Adib
hi
open scope setting and uncheck first line in the last tab. it's about storing point. besides it's better to attache a photo to show your problem.

请先登录,再进行评论。

采纳的回答

Joel Van Sickel
Joel Van Sickel 2021-5-21
Hello Muhammad,
this issue is likely not the scope, but the simulation results. The easiest explanaion of why the results don't make sense is that too large a time step is being used to plot them well. The results can actually be correct, but look wrong because of the large time step. Please set the maximum step size to a small value and your scope data may clean up. If that doesn't work, then something is probably wrong with the model or solver settings such that the simulation is not converging.
Regards,
Joel

更多回答(0 个)

社区

更多回答在  Power Electronics Control

类别

Help CenterFile Exchange 中查找有关 Electrical Sensors 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by