Problem with TCP/IP Send Block in Simulink

13 次查看(过去 30 天)
I am sending hardcoded values to a remote instrument via TCP/IP in Simulink. However, I keep getting the error: 'Error evaluating registered method 'Start' of MATLAB S-Function 'stcpipsb' in 'TestSend2/TCP//IP Send'.' What could be causing this? What configuration parameters might I need to change?

回答(1 个)

Jitesh Patel
Jitesh Patel 2018-7-27
In case anyone else is looking for answer - the TCP/IP blocks requires a server to be running with exact port available.
So running the command "echotcpip('on',50000)" before running simulation will get rid of the error when you are working on one computer and you don't have the actual server available. Note: 1) either the command can be added in some simulink model callback (preload/init) 2) change the port number to match with your need
Hope it helps...

类别

Help CenterFile Exchange 中查找有关 Development Computer Setup 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by