Doubt in resolve error

1 次查看(过去 30 天)
Hi... In simulink i have the next error:
At time 6.08114609259574e-019, simulation hits (1000) consecutive zero crossings. Consecutive zero crossings will slow down the simulation or cause the simulation to hang. To continue the simulation, you may 1) Try using Adaptive zero-crossing detection algorithm or 2) Disable the zero crossing of the blocks shown in the following table.
Why i resolve this?

采纳的回答

Fangjun Jiang
Fangjun Jiang 2011-5-27
You follow the advice by the error message, right? For 1), click menu Simulation>Configuration Parameters ..., select "Solver" in the left column, go to the panel "Zero-Crossing options", select "Adaptive" from the "Algorithm" dropdown menu.
For 2), you must have some blocks that enable the zero-crossing checking. Follow the links in the table, disable the zero-crossing.
BTW, this info can be found in the documentation: Simulink>User's guide>Introduction to Simulink>How Simulink works>Simulating Dynamic Systems>Zero-Crossing Detection

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 General Applications 的更多信息

标签

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by