Sampling time must agree

20 次查看(过去 30 天)
i have an chart which run on event of 1 milli second and i have included the PID library inside sateflow .when ever i click on tune option i get error as sampling time must agree and when i try to run the model i get error asking me to change the sampling time of PID library to -1(inherited ) or constant .

采纳的回答

Guy Rouleau
Guy Rouleau 2013-8-2
Blocks inside Stateflow Simulink functions must inherit their sample time. This is because there is no way for the engine to know when you will call the function.
If the logic in your Stateflow chart systematically calls the Simulink function at 0.001s, there is no problem setting the sample time of the PID block to -1. Results should be the same as if it had a sample time of 0.001s
  1 个评论
Milan
Milan 2013-8-5
when i change the sampling time to -1 and clicked the option tune in PID controller i am getting error as "input parameter of c2d must be positive scalar***"

请先登录,再进行评论。

更多回答(2 个)

Azzi Abdelmalek
Azzi Abdelmalek 2013-8-2
Have you changed the sample time or not yet?
  1 个评论
Milan
Milan 2013-8-5
i had changed it to 1 milli second but i was getting error so i changed it to -1 ,the model was running but when i clicked on tune option of PID controller i got an error "input parameter of c2d must be positive scalar "

请先登录,再进行评论。


Aurelien TCHOUNYA NGATCHOU
Hallo Zusamen,
ich bereite mich vor, gerade bei Matlab-LiveScript zu üben. ich bekomme momentan einen Fehlermeldung "Error using (*) Sampling times must agree" was soll in meinen Matlabscript gändert werden,um diese Simulation durchführen zu können. Vielen Dank

类别

Help CenterFile Exchange 中查找有关 PID Controller Tuning 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by