How to setup buff block in trigger subsystem
16 次查看(过去 30 天)
显示 更早的评论
trigger block parameters: Trigger type:function-call Sample time type:triggered
buffer block parameters: Output buffer size (per channel):256 Buffer overlap:156
err "All sample times for 'untitled/Trigger Subsystem/Buffer' must be discrete. No continuous or constant sample times are allowed"
if trigger block parameters: Trigger type:function-call Sample time type:periodic
buffer block parameters: Output buffer size (per channel):256 Buffer overlap:156
err "Port-based sample time block 'untitled/Trigger Subsystem/Buffer' has a sample time, 100, on output port 1 that does not align with the periodic sample time of function-call subsystem 'untitled/Trigger Subsystem'. Only constant (inf), inherited (-1), or periodic (1) sample times are allowed in the subsystem."
thanks
Only one buffer block in trigger subsystem Ver: MATLAB 7.11 (R2010b) Simulink 7.6 (R2010b)
回答(1 个)
Kaustubha Govind
2011-6-16
The Buffer block has port-based sample times, which are not supported inside triggered subsystems. You may need to create your own S-function that imitates the functionality of the Buffer block, while reconciling its operation within triggered subsystems.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Subsystems 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!