Difference in current length and receive length in bus selector block in simulink
1 次查看(过去 30 天)
显示 更早的评论
hi, im taking image array from ROS node which is of lenght 3072x1 but in simulink im receiving only 128x1 length and not able to retrive rest of the data. please refer below snap -
you can see that recive lenght is 3072 and current length is 128, please help me to solve this problem, im taking rgb image from ROS node and trying to process in matlab, thanks.
0 个评论
采纳的回答
Abhijeet Gadkari
2021-7-27
Hello Kartik,
sensor_msgs/Image is a type of ROS message that contains variable sized sub-message fields.
As shown in the Modify maximum Size of Variable-length Array section of that example, you need to set the correct array-size of the "Data" message field for "sensor_msgs/Image".
Following snapshot of the Simulink model shows this setup.
Let us know if this answers your questions.
- Abhijeet
更多回答(0 个)