photo

Thomas Becker


Thomas Magnete GmbH

Last seen: 2 years 前 自 2015 起处于活动状态

Followers: 0   Following: 0

消息

统计学

All
  • First Review
  • Thankful Level 3
  • Revival Level 1
  • First Answer
  • Solver

查看徽章

Feeds

排序方式:

已回答
Interpretation of Simulink block warning
Thanks for your answer, but, however, I still don't get it. I have attached a simple example model to reproduce the warning (R20...

3 years 前 | 0

提问


Configure elements for code generation
My question relates to code generation for Language = C with the Embedded Coder Is it correct, that the option's Configuration ...

3 years 前 | 0 个回答 | 0

0

个回答

提问


Invalid root Inport/Outport block connection
I don't understand the reasons behind all those rules described in https://de.mathworks.com/help/simulink/gui/invalid-root-inpor...

3 years 前 | 0 个回答 | 0

0

个回答

提问


Interpretation of Simulink block warning
Hello, I'm back to Simulink after a few years of absence. However, I ran into following warning during simulation, which I've n...

3 years 前 | 2 个回答 | 0

2

个回答

提问


Bessel filter transfer function
According to reverse Bessel polynomials from https://en.wikipedia.org/wiki/Bessel_filter#Bessel_polynomials the 4th order looks ...

6 years 前 | 1 个回答 | 0

1

个回答

已回答
Pragmas in SIL simulation
Hi, in the meantime I've got a friendly answer from MathWorks support: "In general, SIL and PIL modes try to closely emula...

6 years 前 | 0

提问


Pragmas in SIL simulation
Hello, we have to insert pragmas for adaptive values and parameters; that works well and the generated code looks fine. Bu...

7 years 前 | 2 个回答 | 0

2

个回答

提问


How can I debug the S-Function generated for SIL simulation with a target from Embedded Coder R2017b?
Hello, based on question <https://de.mathworks.com/matlabcentral/answers/96258>, I have the same question for R2017b. I've a...

7 years 前 | 1 个回答 | 0

1

个回答

提问


Simulink.NumericType vs. Simulink.AliasType
Hello, I'm confused about the use of Simulink.NumericType and Simulink.AliasType objects in R2016b. In the documentation o...

7 years 前 | 1 个回答 | 1

1

个回答

提问


Simulation mode "Normal" for protected models?
Hi community, I've tried to export a model as protected model. That works fine and I can also insert a model block with a lin...

7 years 前 | 0 个回答 | 0

0

个回答

提问


switch with "ignore case" -> switchi
Just a question or a proposal for an enhancement: Has anyone ever wondered, why there isn't an enhanced switch-function for i...

7 years 前 | 2 个回答 | 0

2

个回答

提问


Why is version of MATLAB R2016a = 9.0 instead of 8.7 (like Simulink and Stateflow)
Hi MATLABers, does anyone know, what justifies the decision for using a new major version (9.0) for MATLAB, but not for Simul...

7 years 前 | 1 个回答 | 0

1

个回答

提问


ASAP2 / A2L file: COM_AXIS vs STD_AXIS
Hello, I would like to know, in which cases the Embedded Coder generates axis of look-up tables as STD_AXIS or COM_AXIS. D...

8 years 前 | 0 个回答 | 0

0

个回答

提问


Change "current block"/gcb/gcbh programmatically
Hey MATLABers, is there any way to change the current block in Simulink, which will be returned by gcb/gcbh? I would like to ...

8 years 前 | 2 个回答 | 0

2

个回答

已回答
propogated signal names in logged data
Hello, i ran into the same issue. Give a "real" name to hundreds of signals with propagated names can not be the only solutio...

8 years 前 | 0

提问


When to use numeric or string handles
Hello MATLAB/Simulink programmers, I wonder when to use numeric handles and when to use string handles to Simulink blocks dur...

8 years 前 | 0 个回答 | 1

0

个回答

提问


Simulink Mux block does not accept integer value for "number of inputs"
Hello, I would like to know, why the Mux block's parameter "Number of inputs" does only accept values of type double, whereas...

9 years 前 | 1 个回答 | 0

1

个回答

提问


Matrix representation in generated C code / asap2 file
Hi there, when I generate code from a Simulink model with calibratable vector and matrix parameters, both parameters are gene...

9 years 前 | 1 个回答 | 0

1

个回答

提问


In which release has the TLC function SLibIsRateGrouping been changed to SLibIsPeriodicRateGrouping?
Hello, I came across an error when starting to work with Embedded Coder R2014b due to a changed function name, for example in...

10 years 前 | 0 个回答 | 0

0

个回答