legendbb
自 2012 起处于活动状态
Followers: 0 Following: 0
Professional Interests: signal processing, embedded design
Feeds
提问
Simulink Model Reference, is it possible to reference a subblock?
I need to referenced a submodule. Currently only know model referenced to .slx file. Is it possible to reference A.slx/submdl...
10 years 前 | 1 个回答 | 0
1
个回答提问
Where to find documentation for old releases?
Starting from yesterday of grand upgrading to R2012b, I could not find even documentations for R2012a (online way), which I am c...
12 years 前 | 4 个回答 | 6
4
个回答提问
Simulink on Linux how to get status bar to see simulation progress?
As subject.
12 years 前 | 1 个回答 | 0
1
个回答提问
FPGA in the Loop (timing constraints?)
Where were timing constraints defined for FIL? I've noticed the .ucf file generated. But where was the input to those values?...
12 years 前 | 0 个回答 | 0
0
个回答提问
hdlsetuptoolpath takes no effect on Windows
Playing with FIL demo. Tested both x32 and x64 on XP and Win7. >> hdlsetuptoolpath('ToolName','Xilinx ISE','ToolPath','C:\...
12 years 前 | 1 个回答 | 0
1
个回答提问
Fixed-point precision, why half?
In reading the Mathworks documentation. I really don't understand why fixed-point fractional precison is half of (1/2^FL) inste...
12 years 前 | 1 个回答 | 0
1
个回答提问
How to use macro in Simulink
Tried CUR_DIR = pwd; In Matlab I can do >> ls(CUR_DIR); I can strcat to for a file name and operate on the file. But In S...
12 years 前 | 0 个回答 | 0
0
个回答已回答
[Simulink] How to process 2D vector row by row with gaps between rows
I will answer my own question after finding a solution. Simulink is very obvious at continuous signal for jump start user, co...
[Simulink] How to process 2D vector row by row with gaps between rows
I will answer my own question after finding a solution. Simulink is very obvious at continuous signal for jump start user, co...
12 years 前 | 0
提问
[Simulink] How to process 2D vector row by row with gaps between rows
Dear expert, Need to process a 2D vector, row by row with enable signal. I am trying to select a row (by using DSP toolkit | ...
12 years 前 | 1 个回答 | 0
1
个回答已回答
Simulink SFunction Interface Error: due to insufficient storage
I've given up to have matrix manipulation on x32 bit machine. The model works fine on x64. On x32 machine, I turned to do pro...
Simulink SFunction Interface Error: due to insufficient storage
I've given up to have matrix manipulation on x32 bit machine. The model works fine on x64. On x32 machine, I turned to do pro...
12 years 前 | 1
提问
Simulink how to comb data export to "To Workspace"
A discrete system with enabled subsystem, I'd like to keep only outputs when the enabled subsystem is enabled. It's like save...
12 years 前 | 1 个回答 | 0
1
个回答提问
Simulink SFunction Interface Error: due to insufficient storage
Very *simple* function block, with matrices input and constants total less than 80MB. Sample time 1, Simulation Duration 2. Cod...
12 years 前 | 3 个回答 | 1