已回答
How to dynamically generate a variable name based on the instance of a masked subsystem within a library block in Simulink?
That is right. Passing a string name through mask is difficult if not impossible. But what you really need is to log signals a...

8 months 前 | 0

| 已接受

已回答
How To Include One Instance Of A Block In A Model
I don't see a solution other than, either Don't use subsystem references. Use customized library instead. Or, Ask your vendor ...

8 months 前 | 0

已回答
simulink input signal from function
You can use your script in a "MARLAB Function Block" but need to do some adjustments. Understand this. Your current script does ...

8 months 前 | 1

| 已接受

已回答
Which block should be used for numel function in simulink?
The Width block

8 months 前 | 0

已回答
Finding the toolboxes required for a Simulink Block
I usually go search for "system requirements" for the toolbox. In this case, the toolbox directly needed for that block is "RF B...

8 months 前 | 0

已回答
add_block('powertrainlib/Powertrain','Generator_to_Electric_Motor/Powertrain’);
The full path of the source block is incorrect. The best way to handle this, is to do it manually. If you are able to open the ...

8 months 前 | 0

已回答
Controlling the operator of a relational operator block inside a protected model
In the model, have 5 (for example) relational operator blocks. Each block applies one of the relational operators that you want....

8 months 前 | 1

已回答
Variable Naming in code generation
Take ert.tlc for example, under Code Generation, Identifiers, there are settings that you can change to adjust the Auto-generate...

8 months 前 | 2

| 已接受

已回答
How to get 'gcb' information including a 'for each' index
The "InitFcn" runs only once before each simulation. Whatever info got set to the block is static. The "index" of the "for each"...

8 months 前 | 0

已回答
How to create an ExportedDefine global variable in Simulink for Code Generation?
Create a Simulink.Parameter, specify the storage class as "Define".

8 months 前 | 0

| 已接受

已回答
Simulink Error/Warning: "Signal with under-specified data types" in Motor Control Blockset blocks
set the "Output data type" of that "Data Type Conversion" block to be 'single', instead of leaving it as default.

8 months 前 | 0

| 已接受

已回答
Trubleshooting system model IEEE 906
Both this error message and the popup window indicate that European_LV_graph_1segment.m is not found. The file is listed in the ...

8 months 前 | 0

已回答
Using Signal Logging for Test Harness to Matlab Workspace
doc matlab.unittest.TestResult help matlab.unittest.TestResult

8 months 前 | 0

已回答
Model Advisor configuration fails to save
Make sure to click "Apply" on that check. Save to a .json file. Close and then Open the .json file.

8 months 前 | 2

| 已接受

已回答
Importing data to a 2-D Lookup Table Simulink
The data is not in the right shape to do this. There are too many duplicated (x,y) pairs. For the dupicated (x,y) pairs, the z ...

8 months 前 | 0

已回答
Remove postcodegencommand from Simulink model
https://www.mathworks.com/support/search.html/answers/109355-call-and-execute-matlab-script-function-post-real-time-workshop-bui...

8 months 前 | 0

| 已接受

已回答
Assigning mask parameters to protected models
You need to follow this. https://www.mathworks.com/help/simulink/ug/parameterize-referenced-models.html

8 months 前 | 0

已回答
what happens behind "/"
help /

8 months 前 | 0

已回答
create cell from array with specified size
num2cell(mymatrix)

8 months 前 | 0

已回答
Configure signal logging programmatically (Simulink)
You could re-set all those 200 signal loggings and then set what you want to log programingly. lh=find_system(ModelName,'FindAL...

8 months 前 | 0

已回答
Convert date data in datetime
You could treat the last two digits as duration. Code below is not optimized but gives the correct result. load Data.mat; date...

8 months 前 | 1

已回答
How to configure set_param() per instance for arrays
This is "For Each Subsystem". You need to know how to use it. See the document and examples. https://www.mathworks.com/help/sim...

8 months 前 | 0

| 已接受

已回答
SOC Estimator (Coulomb Counting) gives values above 1 because of current profile. How can I limit this to 1, but descent whenever the current is discharging?
SOC is the integration of current. The "Coulomb Counting" block does not have an option to saturate so your options are limited....

8 months 前 | 1

| 已接受

已回答
How can I assamble n identical blocks in a simscape simulation automathically?
It is possible. Use add_block() to construct the blocks, but repeating 100 times in one model doesn't sound reasonable. Because...

8 months 前 | 0

| 已接受

已回答
How to take out temperature data of one battery cell from battery pack to use it for controller design?
Use the Selector block. The dialog might be intimidating to some. For your case, change the "Inport port size" from "3" to "25",...

8 months 前 | 0

| 已接受

已回答
open .m file GUI in GUIDE
It depends. If the existing tool is developed using GUIDE and the GUI components are saved in a .fig file, then you can use GUID...

9 months 前 | 0

已回答
Simulink equivalent of inputname () or genvarname() for logging
Not sure if you are aware, the MATLAB Function block is typically executed at every simulation step. So even if inputname() and ...

9 months 前 | 1

| 已接受

已回答
Set default font settings for Simulink annotation (comments)
I don't think there is a way to pre-set the default font. But you can do a quick and easy post-processing like this. It will cha...

9 months 前 | 1

| 已接受

已回答
Integrate C Code by Using the MATLAB Function Block in matlab 2015b
The online document for R2015b is not available. The oldest available is below. Notice the "R2018b" in the http address https:/...

9 months 前 | 1

已回答
How do I use Individual license for Matlab and Simulink, but Network License for Simscape?
"Note: In the license file locations, MATLAB will search for a license.dat first and then any .lic in alphabetical order." Easi...

9 months 前 | 0

| 已接受

加载更多