排序方式:

已回答
Problem with discretization of SimPowerSystems model using FixedStepDiscrete solver
Actually I realized I wasn't using discrete RMS. So now its fine. But funny thing is Model Discretizer did not detect the RMS bl...

9 years 前 | 0

| 已接受

提问


Problem with discretization of SimPowerSystems model using FixedStepDiscrete solver
I am adapting a model for VeriStand simulation which requires this solver: Fixed-step discrete (no continuous states). When ...

9 years 前 | 1 个回答 | 0

1

个回答

已回答
specify Simulink block parameters from Excel cells
Indeed it can be done like this thanks. However once I declare my 300 parameters in blocks how do I make assigning values to par...

10 years 前 | 0

提问


specify Simulink block parameters from Excel cells
I have a Simulink model containing over 300 unit delay blocks. So manually entering sample times is arduous process (copy/paste ...

10 years 前 | 2 个回答 | 0

2

个回答

提问


PowerGUI interpretation of current source in phasor simulation
Since sources in phasor must output complex signal and PowerGUI expects real signal this creates problems that cannot be fixed b...

10 years 前 | 0 个回答 | 0

0

个回答

提问


1-phase PLL by Pierre Giroux - can it be used in Phasor simulation?
I tried adapting 1-phase PLL to work in Phasor simulation. I had to get rid of many signal mismatch erros and go through many si...

10 years 前 | 1 个回答 | 0

1

个回答

提问


ideal switch not allowed in phasor simulation?
When I try to run simulation with PowerGUI set to phasor simulation I have this error: _Warning: The following SimPowerSystem...

11 years 前 | 1 个回答 | 0

1

个回答

提问


Increasing simulation speed in heavy presence of ideal switches
I have a very stiff low voltage network model with over 150 ideal switches. I have noticed that the more switches I add the mor...

11 years 前 | 1 个回答 | 0

1

个回答

已回答
Current keeps flowing no matter if breaker is open or closed
Hi Arne, For me it worked by setting the solver to ode23tb robust. This issue is described in breaker help, but a bit vague. ...

11 years 前 | 0

已回答
empty signal coming into minimum block problem
Hi Kaustubha, thanks you very much for replying. Stop doesn't really help but let me try to explain the system in more physi...

11 years 前 | 0

提问


empty signal coming into minimum block problem
I have a Find non-zero block connected Min block. Find non-zero outputs a variable size matrix that shrinks for one element in e...

11 years 前 | 2 个回答 | 0

2

个回答

已回答
Current keeps flowing no matter if breaker is open or closed
I wanted to add that the only time system notices the difference between open and closed breaker is when I remove snubbers. But ...

11 years 前 | 0

提问


Current keeps flowing no matter if breaker is open or closed
I have AC current sources connected with each other in parallel and to AC voltage source also in parallel. In each branch curren...

11 years 前 | 9 个回答 | 1