已回答
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hi Manisha, We did find a kind of solution. We installed the old NI-DAQ 7.4.4. driver and we do have access to discontinuous...

12 years 前 | 0

已回答
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
There is no AI.Channel.Coupling Here is AI.Channel: Index: ChannelName: HwChannel: InputRange: SensorRange: UnitsRan...

12 years 前 | 0

已回答
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hi Manisha, Thank you for answering. In both NI and Data Acquisition Toolbox, the property 'InputType' is set to Pseudodiffe...

12 years 前 | 0

提问


Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hello, I have some trouble with the data acquisition toolbox. The simple program below works great for transient signals cen...

12 years 前 | 4 个回答 | 0

4

个回答