Operating point restore interface checksum mismatch
Description
Use this check to ensure that the interface checksum is identical to the model
checksum before loading the Simulink.op.ModelOperatingPoint
object
specified using the Initial state
parameter.
Category: Diagnostics
Settings
Default:
warning
none
Simulink® software does not compare the interface checksum to the model checksum.
warning
The interface checksum in the operating point is different than the model checksum.
error
When Simulink detects that a change in the configuration settings occurred after saving the operating point, it does not load the
ModelOperatingPoint
object and reports an error.
Command-Line Information
Parameter:
OperatingPointInterfaceChecksumMismatchMsg |
Value:
'warning' | 'error' |
'none' |
Default:
'warning' |
Recommended Settings
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | No impact |
See Also