Variable speed FOC motor drive
2 次查看(过去 30 天)
显示 更早的评论
The user guide of Simpower systems has a demo file of variable speed FOC motor drive. Reference : Building Your Own Drive : Systems with electric drives.
On referring to the model implemented, the formulas used for 'iqs* calculation' and 'Teta calculation' use phir for calculation purpose. The function block shows that a value of 1e-3 mWb is added to Phir value. The value has not been indicated in the formulas expressed below. I need to know, why that value of 1mWb has been added to Phir value in calculation.
0 个评论
回答(1 个)
Joel Van Sickel
2020-12-1
This is a simple trick to avoid divide by 0.
This answer is part of a MATLAB Answers cleanup effort for unanswered questions that are outstanding.
0 个评论
社区
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Simscape Electrical 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!