What are the underline assumptions while drawing the PowerPattern of an array in PlotResponse ?

1 次查看(过去 30 天)
What is the input power assumed while drawing the power pattern of an array, what are the units of power pattern ? and at what distance power pattern is plotted ? Is there any provision to change the default settings for drawing power pattern ?
I assume the input power is 4*pi Watts (i.e. 1 W/steradian), and power pattern is plotted at the surface of 1m sphere, can anybody confirm ?

回答(1 个)

Honglei Chen
Honglei Chen 2015-8-11
Hi Raza,
The power pattern can be considered as plotted on the surface of a sphere. The radius doesn't matter too much as long as it's in the far field. I don't think it assumes the unit power pattern. It simply plots the magnitude square of the field pattern. The main information conveyed in the field pattern is the relative spatial dependency. So in general only the shape matters unless you look into the directivity pattern which uses an isotropic pattern as a reference.
HTH

类别

Help CenterFile Exchange 中查找有关 Get Started with Phased Array System Toolbox 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by