![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1290280/image.png)
Simscape phase to phase voltage measurement is not correct?
1 次查看(过去 30 天)
显示 更早的评论
Hi, Do you have any idea why the phase-phase voltage and current has some DC component( I mean it is a bit shifted upward!)!? The line to line voltage is alright and placed in the center (plot 2) but the phase to ground voltage and current are wrong!
<<
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/159106/image.jpeg)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/159107/image.jpeg)
>>
0 个评论
回答(1 个)
Sabin
2023-2-9
This is due the way the electrical reference is connected. to the negative terminal. To get the voltage centered in 0 what is needed is to alter the circuit such that the ground is not anymore connected to the negative terminal. You can use two DC voltage sources, each with half of the total DC voltage and the electrical reference between them.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1290280/image.png)
Alternativeley, you can use to capacitors on the DC side and put the electrical reference between them.
0 个评论
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!