how to fix the following error?

7 次查看(过去 30 天)
dear Seniors and Experts I need solution for following code kindly help me to fix it .
data is
y=195840*2 double
fs=48000
t=0:0.001:2; % 2 secs @ 1kHz sample rate
x=chirp(t,0,1,150); % Start @ DC, cross 150Hz at t=1sec
F = 0:.1:100;
[y,f,t,p] = spectrogram(x,256,250,F,1E3,'yaxis');
% NOTE: This is the same as calling SPECTROGRAM with no outputs.
surf(t,f,10*log10(abs(p)),'EdgeColor','none');
axis xy; axis tight; colormap(jet); view(0,90);
xlabel('Time');
ylabel('Frequency (Hz)');
[y,fs]=audioread('Mithe Mustafa Tey 5sec.mp3');
NW = round(fs*0.250);
[S,F,T,P] = spectrogram(y,NW,[],[],fs);
Error using spectrogram>chkinput (line 252)
X must be a vector (either row or column).
Error in spectrogram (line 166)
chkinput(x);
while I click on line 252 and 166 it shows this
line 252 = error(message('signal:spectrogram:MustBeVector', 'X'));
line 166 = chkinput(x);

采纳的回答

Yasir Ali
Yasir Ali 2019-3-26
Thanks Dear walter If I wish to plot both channels then how to do that?
  2 个评论
Walter Roberson
Walter Roberson 2019-3-26
subplot(1,2,1)
spectrogram(y(:,1), NW, [], [], fs);
title('left channel')
subplot(1,2,2)
spectrogram(y(:,2), NW, [], [], fs);
title('right channel')
Jan
Jan 2019-4-4
@Yasir: This is not an answer, which solves the question. Marking it as "accepted" means, that your problem is solved by this answer. Please post comments in the section for comments.

请先登录,再进行评论。

更多回答(1 个)

Walter Roberson
Walter Roberson 2019-3-26
Your mp3 is stereo, 2 channels. spectrogram() can only process one channel at a time.
You need to do one of the following:
  1. Choose one of the two channels and only process that one; or
  2. combine the two channels into one, such as by using mean(); or
  3. call spectrogram twice, once for each of the channels.
  6 个评论
Yasir Ali
Yasir Ali 2019-3-26
编辑:Walter Roberson 2019-3-30
Dear walter one last guideline require I found your comments very helpful
In above code I have try to get frequency response of audio in milisecond is it good code for getting frequency in miliseconds? ?
And when I try to get spectrum above 300 like 350 ms or more than error comes index dimension exceeds.
Walter Roberson
Walter Roberson 2019-3-30
I am not sure. My calculation at the moment is that with your window of 256 that you would get resolution to about 375 Hz, but I do not trust those calculations at all.

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 Time-Frequency Analysis 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by