How can I synchronize analog intputs and outputs using Data Acquisition Toolbox?
4 次查看(过去 30 天)
显示 更早的评论
MathWorks Support Team
2011-11-15
编辑: MathWorks Support Team
2022-3-3
I am using Data Acquisition Toolbox and would like to synchronize an analog input and analog output object.
采纳的回答
MathWorks Support Team
2022-2-24
编辑:MathWorks Support Team
2022-3-3
Synchronization of analog inputs and outputs can only be achieved through the use of hardware triggering. It is also possible to trigger two analog input objects at approximately the same time using software triggering, however they will not be synchronized.
If you wish to use hardware triggering, you will need to make sure that your hardware is capable of the type of synchronization you want to do. For example, some boards may have separate trigger pins for analog inputs and outputs. Please see the following page for a list of the hardware supported by Data Acquisition Toolbox:
The following example shows how to use analog input channels and analog output channels together with a single Session object running near simultaneous.
2 个评论
Walter Roberson
2013-11-22
编辑:MathWorks Support Team
2018-4-5
Updated links:
For Legacy: https://www.mathworks.com/help/releases/R2015b/daq/starting-multiple-device-objects.html?searchHighlight=starting%20multiple%20device%20objects and see also https://www.mathworks.com/help/releases/R2015b/daq/configuring-analog-input-triggers.html?searchHighlight=Configure%20Analog%20Input%20Triggers and https://www.mathworks.com/help/releases/R2015b/daq/examples/using-analog-input-triggers.html
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Data Acquisition Toolbox Supported Hardware 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!