Does the "Load Impedance" field in the "Output Port" block accept complex numbers in RF Blockset 2.3 (R2008b)?

1 次查看(过去 30 天)
I would like to know if the "Load Impedance" field in the "Output Port" block (from the RF blockset library) can accept a complex number (that is, capacitive output (real and imaginary number)). The reason for this question is because I want to use the following configuration: Input Port -> General Passive Network -> Output Port wherein Terminating load impedance: ZL = 2 kΩ 3 pF
The Help Documentation for Transmission Line, S-Parameters Passive Network, S-Parameters Amplifier and S-Parameters Mixer blocks explicitly mention that complex impedances are allowed. This is not the case for the "Output Port" block.

采纳的回答

MathWorks Support Team
The "Load Impedance" of the "Output Port" block does accept a complex number.