Community Profile

photo

Dr Narayanaswamy P R Iyer


Last seen: 5 days 前 自 2017 起处于活动状态

M.E.(Power Electronics and Drives), UTS, NSW, Australia. Ph.D.(Power Electronics and Drives), Curtin University of Technology, Perth, WA, Australia. Received B.Sc.(Engg)(Electrical) and M.Sc.(Engg)(Power systems) degrees from Kerala University and Madras University respectively. Published the following text books: 1) "Power Electronic Converters: Interactive Modelling Using Simulink", CRC Press, 2018. 2) AC to AC Converters: Modelling, Simulation and Real-Time Implementation Using SIMULINK", CRC Press, 2019. Present MATLAB Version: R2022a. MATLAB License Number: 40513742 Operating System: Microsoft Windows 10 Home Version 10.0 (Build 14393) Java Version: Java 1.8.0_121-b13 with Oracle Corporation Java HotSpot(TM) 64-Bit Server VM mixed mode ----------------------------------------------------------------------------------------------------- P.R. NARAYANASWAMY. Dr NARAYANASWAMY P R IYER EMAIL: nswamy.iyer@gmail.com

Programming Languages:
C++, C, Java, MATLAB, SQL, HTML, Fortran
Spoken Languages:
English, Hindi

统计数据

  • Knowledgeable Level 1
  • Thankful Level 2
  • 3 Month Streak
  • First Answer
  • Thankful Level 1

查看徽章

Content Feed

排序方式:

已回答
Run a simulink model for a certain amount of time and pause at T=0.5 more than 9h
You have to click 'view diagnosticks' at the bottom screen and follow the instructions. P.R. NARAYANASWAMY DR. N P R IYER...

14 days 前 | 0

已回答
Are there any MATLAB Simulink models for Indirect Matrix Converters, especially Sparse Matrix Converter?
You may refer to my text book given below: NARAYANASWAMY P R IYER: "AC TO AC CONVERTERS: MODELING, SIMULATION AND REAL-TIME...

3 months 前 | 0

已回答
How to find THD?
Check the result by setting sample time to zero and also by setting it to 50e-6 Second.

3 months 前 | 0

已回答
Hi. In Simulink modeling, what can we do to ensure that the switching waveforms of the duty cycle and 1-duty cycle are not in phase?
Connect q1 to NOT gate and use Data Type Conversion block if error message occurs.Output of NOT gate is q3. Alternatively connec...

4 months 前 | 0

已回答
Better solver for simscape power electronics simulation
In case of uncertainty as to which solver to be used, select AUTO solver selection mode from the drop down menu.

5 months 前 | 0

已回答
What solver settings is best for a closed loop Dual active bridge simulation??
Usually ode23tb will be sufficient. If you are unsure select auto (automatic solver selection) mode.

10 months 前 | 0

已回答
What is an efficient way to do PID tuning in a model with long computing time?
You may use Ziegler-Nicholas step response or else frequency response method for tuning PID controllers.

10 months 前 | 1

| 已接受

已回答
Controling multiple switches in a multiple input DC-DC converter
Hi Mohammad Alsalman: You have to use combined combinational and sequential logic. I give below how to generate gate pulse fo...

1 year 前 | 0

已回答
Controling multiple switches in a multiple input DC-DC converter
Hi Mohammad Alsalman: You have to use combined combinational and sequential logic. I give below how to generate gate pulse fo...

1 year 前 | 0

已回答
Explaining the function of certain blocks
Hi: Assume that pulse generator output is vg and armature voltage control signal output is vcon. The top mux output, vcon, bot...

1 year 前 | 0

已回答
I want to do Primary frequency response of DFIG Wind Turbine in script form (MATLAB).
Hi: Please refer to the following text book: NARAYANASWAMY P R IYER: "Power Electronic Converters Interactive Modelling Usin...

1 year 前 | 0

已回答
How to find people to work on a collaborative project
I can work if the project falls within the broad area of Power Electronics and Drives. DR. NARAYANASWAMY P R IYER EMAIL: ns...

1 year 前 | 0

| 已接受

已回答
I want to do Primary frequency response of DFIG Wind Turbine in script form (MATLAB).
Hi: Try using EMBEDDED MATLAB Function in SIMULINK.

1 year 前 | 0

已回答
How to find THD?
If your model is in SIMULINK, use THD module from Simscape / Electrical / Specialized Power Systems / Sensors and Measurements ...

1 year 前 | 0

已回答
How To Input Duty Ratio into Pulse Generator
Enter period as 20e-6 Seconds and pulse width as 50.

1 year 前 | 1

已回答
Torque control of PMSM motor- Need help
Hi: Torque set point is the rated machine torque. Torque set point is required to calculate id and iq reference values and stat...

1 year 前 | 0

已回答
Help understanding transformers in simulink
The results appears alright. The spikes in waveform could be due to inductance of transformer windings compared to their resista...

1 year 前 | 0

已回答
Defining pmsm parameters for delta configuration
The resistance and inductance values must be multiplied by 2/3 to get the per phase values for delta configuration. Thanks. DR....

2 years 前 | 0

已回答
link a full bridge DC/AC to an induction machine
Hi: The PWM output is a gate pulse and is given to the G input of inverter through a four pulse gate multiplexer. The + and - te...

2 years 前 | 0

已回答
Why does differentiating PID feedback break the system?
Clock module.

2 years 前 | 0

已回答
Why does differentiating PID feedback break the system?
Hi: Instead of integrator at the output of convert to RPS module, use a multiplier block along with time block or time module an...

2 years 前 | 0

已回答
How to develop Behavioral model of gate driver integrated circuit using specialized power system library blocks?
Shiny: Please refer to the following text book: NARAYANASWAMY P R Iyer: "AC to AC Converters Modelling, Simulation and Real-T...

2 years 前 | 0

已回答
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
For 8 V output, your duty-ratio should be 2/3 (0.67) for given input voltage.

2 years 前 | 0

已回答
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
TF is one method. You know the desired output voltage and duty-ratio D. Use this in the model to get open loop voltage response....

2 years 前 | 0

已回答
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
You have NOT mentioned anything about triangle carrier frequency. First obtain output voltage response without PI controller. Th...

2 years 前 | 0

已回答
my firing angle on this triac does not work correctly ?
For switching thyristors, you may refer to the following text book: NARAYANASWAMY P R IYER: "Power Electronic Converters Inte...

2 years 前 | 0

已回答
Problem At Sistem On Chip (SOC,PIL) Example Application
Most probably it could be due to insufficient RAM memory. Please check your PC RAM with the version of MATLAB specific requirem...

2 years 前 | 0

已回答
Problem At Sistem On Chip (SOC,PIL) Example Application
Check your PC RAM memory with that specified by MATHWORKS for the MATLAB version used.

2 years 前 | 0

已回答
Can you open an older simulink models and reference models in a newer version and build from the newer simulink?
I think the model developed using 2013b in Simulink can be opened with 2020b.

2 years 前 | 0

已回答
Analog PID controller to Discrete PID controller
Analog PID Controller. Find TF of analog PID Controller and use command c2d in MATLAB.

2 years 前 | 0

加载更多