Unspecified bus object at root Outport block
Diagnostic action to take when root Outport block of referenced model does not specify bus object for bus output
Model Configuration Pane: Diagnostics / Connectivity
Description
The Unspecified bus object at root Outport block configuration
parameter determines the diagnostic action to take when generating a simulation target
for a referenced model if any root Outport block of the referenced model receives a bus and does not specify a
Simulink.Bus
object.
Settings
warning
(default) | none
| error
none
The software takes no action.
warning
The software displays a warning.
error
The software terminates the simulation and displays an error message.
Tips
This diagnostic applies only when a model is used as a referenced model. Simulating or updating the model on its own does not invoke the diagnostic.
A root Out Bus Element block does not require a
Simulink.Bus
object for the corresponding Model block to output a bus.When a root Outport block receives a virtual bus and does not specify a
Simulink.Bus
object, the corresponding Model block output is a vector.
Recommended Settings
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | error |
Programmatic Use
Parameter:
RootOutportRequireBusObject |
Value: 'none' | 'warning' | 'error' |
Default: 'warning' |
Version History
Introduced in R2006b