HDL Verifier and FPGA in the loop

37 次查看(过去 30 天)
shreyas
shreyas 2012-6-2
Hello All,
I am trying to use FPGA in the Loop (FIL) using HDL verifier and simulink, but I keep getting the error:
Did not receive version information from the hardware. You must have a valid connection, a compatible development board, and compatible versions of the block and FPGA programming file.
My board atlys board and I am not able to get reply from the board when I ping it. Can anyone tell me where I am wrong?
  1 个评论
Walter Roberson
Walter Roberson 2012-6-2
I received your email, but this is not a topic I have experience with.
The MAC address would be 12 hexadecimal digits.
There are different meanings of "ping" in use. The most common meaning requires knowing the IP address of the destination, but does not require knowing the MAC address. An IP address such as 192.168.0.1 would be common.

请先登录,再进行评论。

回答(8 个)

Tao Jia
Tao Jia 2012-8-8
There is a trouble shooting section in the HDL Verifier documentation. Try to see if that one helps you. It's possible a network setting issue.

Pablo Medina
Pablo Medina 2016-9-15
hi, I am getting the same error. Did you solve your problem? Could you give me a hint?
Thanks, for the future answer.

Prashant Funde
Prashant Funde 2017-8-3
If this problem is solved please give me some hint.

LIANG GUO
LIANG GUO 2019-5-10
id not receive version information from the hardware. You must have a valid connection, a compatible development board, and compatible versions of the block and FPGA programming file.
Component: Simulink | Category: Model error

Ricardo Mejia Mertel
Hello, I know the thread is quite old but anyone was able to solve the problem?
best regards,
Ricardo

hbot
hbot 2021-1-22
编辑:hbot 2021-1-22
It helped in my case to readjust Windows network adapter "TCP/IPv4" properties to match the network settings of the evaluation board. Make sure that the subnet number is the same, but the host number is different. For example: PC IP 192.168.0.1, board's IP 192.168.0.2. Try pinging the board in Windows cmd (ping 192.168.0.2) - it must work.
The strange thing is that all connection checks passed in MATLAB (HDL Workflow advisor, vefircation during board's support package installation) with incorrect network settings, only the model simulation didn't run, until I set the correct network IP.

Mohamed BAGHDADI
Mohamed BAGHDADI 2021-1-23
Did not receive version information from the hardware. You must have a valid connection, a compatible development board, and compatible versions of the block and FPGA programming file.
Anyone was able to solve the problem?
PS: I am using Matlab 2019b, altera cyclone IV GX, Quartus prime 18.1 and JTAG Connection
best regards,
  5 个评论
dechen Ai
dechen Ai 2022-7-15
The same with you. Have you resoled the problem?
I am using Matlab 2019b, Xilinx zynq xc7z010clg400-1 FPGA baord, Vivado2017.4 and JTAG Connection.
壹 王
壹 王 2023-6-2
Hello!I receive the same error information.
I used HS2 JTAG cable, xilinx zynq XC7z020400-2, matlab 2021a. Did any fixed this problem ?

请先登录,再进行评论。


Anas EL-FECHTALI
Anas EL-FECHTALI 2023-5-22
i'm using matlab 2022b to coimplemente on xilinx zynq XC7z020 , but i get an error :
Did not receive version information from the hardware. You must have a valid connection, a compatible development board, and compatible versions of the block and FPGA programming file.
Component:Simulink | Category:Model error
Is here someone who had the same issue?
  4 个评论
Anas EL-FECHTALI
Anas EL-FECHTALI 2023-6-13
编辑:Anas EL-FECHTALI 2023-6-13
hello, i solved this issue by respecting matlab vivado compatibility.for matlab 2020Rb you have to get vivado simulator 2020.2, for others:
  • R2023a: Xilinx Vivado 2022.1
  • R2022b: Xilinx Vivado 2020.2
  • R2022a: Xilinx Vivado 2020.2
  • R2021b: Xilinx Vivado 2020.1
  • R2021a: Xilinx Vivado 2019.2
  • R2020b: Xilinx Vivado 2019.2
  • R2020a: Xilinx Vivado 2019.1
  • R2019b: Xilinx Vivado 2018.3
  • R2019a: Xilinx Vivado 2018.2
  • R2018b: Xilinx Vivado 2017.4
  • R2018a: Xilinx Vivado 2017.2
  • R2017b: Xilinx Vivado 2016.4
  • R2017a: Xilinx Vivado 2016.2
  • R2016b: Xilinx Vivado 2015.4
  • R2016a: Xilinx Vivado 2015.2
  • R2015b: Xilinx Vivado 2014.4
  • R2015a: Xilinx Vivado 2014.2
  • R2014b: Xilinx Vivado 2013.4
sencondly, you have to install Hdl verifier support packages , go to Add-ons ---->Get Add-ons in matlab and configurate it. then launch run in your simulink design.
Anas EL-FECHTALI
Anas EL-FECHTALI 2023-6-20
sure, my e-mail :elfechtali.forwork.anass@gmail.com