已回答
I am not able to add Electrical blocks from Simulink Simscape
You do not have an active license for Simscape Electrical. The 'ver' command does NOT give you an extract of all toolboxes for ...

1 year 前 | 0

已回答
Can anyone explain me what this symbol signifies?
Looks like Divide.

1 year 前 | 0

已回答
C function calls and multiple calls from simulink
I do not deeply understand the issue, but I would like to propose the following. Create a Simulink Function block in your model ...

1 year 前 | 0

已回答
Cannot override parameters in Simulink model configuration reference
You can only adapt the Configuration Parameters object, not the Configuration Reference object. You need to adapt the Configurat...

1 year 前 | 0

已回答
Using discrete integrator block with embedded coder
I also use 'my own' integrator blocks or implementations with Embedded Coder. I work in an Export-Function model where it gener...

1 year 前 | 0

已回答
split a pulse train into two outputs in simulink
Use Compare To Constant blocks on the input signal and then Logical Operator blocks. E.g.: signal > 3 AND signal < 4 => first ...

3 years 前 | 0

已回答
Make matlab use single as standard for code generation
In the 'Configuration Parameters', under the section 'Math and Data Types', choose 'single' for the option 'Default for underspe...

3 years 前 | 0

已回答
Is there a way to eliminate rate scheduler task from generated code when we have two different time sampling for blocks in model ?
Structure your model as an Export-Function. Each task will appear in generated code without task scheduler. The task scheduler ...

3 years 前 | 0

提问


New MATLAB Answers filtering does not allow multiple selections
So apparently MATLAB Answers was updated. It now received a cleaned up frontpage which seems to push people in posting answers, ...

3 years 前 | 1 个回答 | 0

1

个回答

已回答
How do I create a switch statement using 1 variable rather than multiple separate ones in Stateflow?
Thank you for the clarification of your example code. The code example you show is a statemachine implemented in code. The stat...

3 years 前 | 0

| 已接受

已回答
How to find if the Simulink model is used for code generation
System Target File will be 'ert.tlc' if the model is configured for code generation. strcmp('ert.tlc',get_param('mymodel','Syst...

3 years 前 | 0

| 已接受

已回答
Simulink Product Block Dimension Issue.
You need to set the 'Multiplication' option of your Product block to 'Matrix(*)'.

3 years 前 | 1

| 已接受

已回答
Simulink Split a signal
Just branch the line: You can start from the block you want the line to go to, click and drag it on the line you want the con...

3 years 前 | 0

| 已接受

已回答
How to create connections?
On the left (in blue) you have used blocks of the Simscape Foundation Library. On the right (in black) you have used blocks of ...

3 years 前 | 0

已回答
connecting 6 phase PMSM with IGBT(simscape)
Do you want to use the PMSM (Six-Phase) block of Simscape? It has an ABC and XYZ port. I think you should combine three outputs ...

3 years 前 | 0

| 已接受

已回答
AMD ryzen 7 5700u or intel i7 1165?
Since Simulink is a single threaded process, it benefits from faster cores, not from more of them. The Intel is a 4-core CPU, th...

3 years 前 | 0

提问


'Generated code will not preserve the expression' warnings
Warning 1 I am getting the following warning on a Simulink.Parameter object stored in my Data Dictionary: Parameter object...

3 years 前 | 0 个回答 | 0

0

个回答

已回答
Access and change variable in Model Workspace within the Simulink simulation
You cannot change objects in the Model Workspace during simulation. Or it's not intended for this at least. Use Data Store Memo...

3 years 前 | 0

已回答
Simulink: Can you invert the constant block?
To Workspace block

3 years 前 | 0

已回答
How to use a real current source?
Instead of using an ideal current source, use an ideal voltage source with a resistor in parallel.

3 years 前 | 0

已回答
How to allow only sequences that have had the same value for 5 seconds (in Simulink)?
Using only blocks, I think this should do the trick:

3 years 前 | 1

已回答
How to decode a UDP packet without byte unpack
You can reassemble those 8 bytes into a 64 byte double by applying a bitshift to each byte to its correct position, using a bito...

3 years 前 | 0

| 已接受

已回答
Matlab/Targetlink Commands & Documentation
TargetLink is not a MathWorks product. You should find documentation from dSPACE support.

3 years 前 | 0

已回答
Where is the "Treat as atomic unit" option for Function-Call Subsystem?
On my installation (R2020b) the 'Treat as atomic unit' is checked and greyed out. I believe a Function-Call Subsystem is always ...

3 years 前 | 0

| 已接受

已回答
Simulation or Simulink?
I believe you want to compare performing image processing and classification using a MATLAB script or using a Simulink model. U...

3 years 前 | 0

已回答
Online polynomial linear curve fitting in Simulink
If you have the DSP Systems Toolbox you can use the Least Squares Polynomial Fit block. Standard Simulink does not have an alte...

3 years 前 | 0

| 已接受

已回答
Resetting Integrator by output of state flow in Simulink
Simulink cannot know which action to do first, since they depend on eachother. If you take output of the Stateflow s, reset the ...

3 years 前 | 0

| 已接受

提问


Get exact value from Scope cursor in Simulink
I am using the vertical Cursors in a Scope window to find the signal value. However, the value only displays three significant n...

3 years 前 | 1 个回答 | 2

1

个回答

已回答
How to change evaluation time of a Matlab Function in Simulink
If you put a MATLAB function block in your model, it will evaluate the MATLAB function code at each sample time. (depends on you...

3 years 前 | 0