photo

sst


自 2011 起处于活动状态

Followers: 0   Following: 0

统计学

  • Thankful Level 3
  • First Answer

查看徽章

Feeds

排序方式:

提问


Passing non-scalar data for multiple columns using runstoredprocedure
Hello, I am trying to pass non-scalar data into an SQL Server stored procedure using the "runstoredprocedure" function in the Da...

1 year 前 | 1 个回答 | 0

1

个回答

提问


uifigure alternatives for gcf, gcbf, gco, gcbo, gca, and any other legacy figure based functions
Hello, I was wondering if any alternatives that work with the new uifigure windows are being developed for gcf, gcbf, gco, gcbo,...

1 year 前 | 1 个回答 | 0

1

个回答

提问


How do we select between multiple function call signals depending on a switch input?
Hello, I am trying to set up a Simulink construct that selects between multiple function call signals, which happen to be output...

5 years 前 | 0 个回答 | 0

0

个回答

提问


Obtaining signal units post compilation
Hello, is it possible to obtain the signal units associated with a port, post compilation? I am trying to find a property simila...

6 years 前 | 1 个回答 | 0

1

个回答

提问


Simulink errors out with message "**** Error ****" - no other information
Hello, what could cause Simulink to error out with the message "**** Error ****" with no other information? I am using MATLAB R2...

6 years 前 | 0 个回答 | 0

0

个回答

提问


Is it possible to force mask initialization externally?
I was wondering, is it possible to force mask initialization from an external command somehow?

8 years 前 | 1 个回答 | 3

1

个回答

提问


Legacy implementation of strtrim prior to R2016a
It looks like strtrim changed in R2016a to not trim significant whitespace characters. However, I have a need for a legacy imple...

8 years 前 | 1 个回答 | 0

1

个回答

提问


Flag that indicates source of execution for Simulink block initialization code
Is there a recommended way to tell within Simulink block initialization code, whether it is being executed during a Simulink Cod...

8 years 前 | 0 个回答 | 0

0

个回答

提问


Exclusion of blocks that interact with the MATLAB engine during code generation
I am trying to develop Simulink blocks that interact with the MATLAB engine during simulation, but are automatically excluded fr...

9 years 前 | 1 个回答 | 0

1

个回答

提问


How can we obtain a list of enumeration data types defined using successive calls to Simulink.defineIntEnumType?
Hello, I was wondering, is there a way to obtain a list of enumeration data types defined using successive calls to Simulink.def...

9 years 前 | 0 个回答 | 0

0

个回答

提问


Best Practices - Large Virtual Buses entering an Atomic Subsystem
I was wondering, is there any reason large virtual buses should be not be inputs to atomic subsystems, from a memory consumption...

9 years 前 | 0 个回答 | 0

0

个回答

提问


Using an enumerated data type defined within a MATLAB package folder with a Simulink.Parameter object
Hi, I am trying to use a Simulink.Parameter object with an enumerated data type in a Simulink model (R2011b). I have attached th...

10 years 前 | 0 个回答 | 1

0

个回答

已回答
How do I add a value in ONE element of a matrix in a for loop?
This should not require a for loop: x = [-20:-1, 1:20].'; Amatrices = arrayfun(@(X) [1+X, 1; 2, 5], x, 'UniformOutput', ...

10 years 前 | 0

提问


Code generation - passing a large virtual bus to an enabled (atomic) subsystem
Hello, I was wondering how the memory allocation takes place when a bus containing a large number of signals (around 10000 signa...

10 years 前 | 0 个回答 | 0

0

个回答

提问


How can I allow a masked subsystem to modify the underlying block without breaking its link to a library?
Hello. I have a masked subsystem residing in a library. A callback to one of the parameters of the masked subsystem changes the ...

10 years 前 | 0 个回答 | 1

0

个回答

提问


Simulink Coder - Building individual components of models separately and then linking them
Hi, building a large model with Simulink Coder can take a substantially long time. Is it possible to build individual components...

11 years 前 | 1 个回答 | 0

1

个回答

提问


Database Toolbox: Talking to MS Access using JDBC
Hi, I am attempting to use Sun's JDBC-ODBC bridge to connect to Microsoft Access using the Database Toolbox. Configuration: M...

12 years 前 | 1 个回答 | 0

1

个回答

提问


Automatic signal name propagation through buses not working as intended
Hi, I am trying to get signal rename operations to be propagated automatically through buses. However, it doesn't seem to be wor...

13 years 前 | 1 个回答 | 0

1

个回答

提问


Getting a handle to a function inside a package folder
Hi, suppose I want to get a handle to a function inside a package folder +mypackage. I would have assumed that the following ...

13 years 前 | 0 个回答 | 1

0

个回答

已回答
Specifying discrete sample time for variable-size signals
Hi Kaustubha, while the variable-size signal was indeed a discrete sample time signal, the main input signal (In1) to the assign...

13 years 前 | 1

| 已接受

提问


Specifying discrete sample time for variable-size signals
Hi, I am trying to use the inherit sample time setting (-1) for the Assignment block, using a variable-size signal as an index v...

13 years 前 | 2 个回答 | 0

2

个回答

提问


Simulink: Obtaining propagated signal names programmatically
Hi, I am trying to obtain the propagated signal name for a signal programmatically. For example: porthandles = get(gcbh, 'Por...

13 years 前 | 1 个回答 | 0

1

个回答

提问


loadlibrary calls lcc by default
Hi, I am using R2010b SP1 running on Windows XP Professional SP3 (32 bit). I am trying to use loadlibrary to access a DLL within...

13 years 前 | 1 个回答 | 0

1

个回答