Suppose you log a signal generated from a Random
Number block to the Simulation Data Inspector. You can get descriptive statics
about the logged signal using the Simulink.sdi.Signal object.
Access the Simulink.sdi.Signal object for the signal named
mySig.
Find the mean sample value using the mean function.
meanVal = mean(sigObj)
meanVal =
0.0708
To find the mean sample value near the end of the simulation, specify the starting
time. For example, to find the mean value in the last two seconds of the simulation,
specify startTime as 8.
meanValEnd = mean(sigObj,8)
meanVal =
0.1382
To find the mean sample value in a specific interval, specify the start and end time
to search in. For example, find the mean sample value between 2 seconds and 4
seconds.
Input signal, specified as a numerical scalar Simulink.sdi.Signal
object.
To find the mean value of a composite signal element, such as a bus element, or the
mean value of the real or imaginary part of a complex signal, use the
Children property. The Children property
contains Simulink.sdi.Signal objects that make up the composite signal
or real and imaginary parts of the complex signal.
For composite signals, access elements in the Children
property by index.
For complex signals, the first element in the Children
property is the real part of the complex signal and the second element is the
imaginary part.
Example: meanVal = mean(complexSig.Children(1))
Start time, specified as a nonnegative scalar less than endTime.
This time specifies the beginning of the time interval in which to find the mean.
End time, specified as a nonnegative scalar greater than
startTime and less than the simulation time. This time specifies
the end of the time interval in which to find the mean.